Sartorius AirPort MD8

Air Samplers


Features

airport_images2

Applications

Proactive companies are realizing the importance of active air sampling as an integral part of their QC protocol. The Sartorius AirPort MD8 is the new air sampler for the pharmaceutical, biotechnology and the food and beverage industry. The AirPort is also used in hospitals for environmental protection and occupational safety.

microorganisms2

Performance

Weighing in at only 5.5 lbs, the AirPort is portable and battery operated so it can be used everywhere. The battery offers 4.5 hours of sampling time before needing to recharge, and can still be used while the battery is recharging. The battery level is clearly indicated so constant performance during sampling is guaranteed. The AirPort is ergonomically designed and easy to clean. It has flexible options for customized use, including adjustable air throughput and air flow rate. The parameters last used are stored even after the automatic shut-off. With the optional calibration unit, the air sampler can be calibrated on site.

microorganisms1

Gelatin Membrane Filter Method

The AirPort MD8 utilizes the gelatin membrane filter method for collecting airborne microorganisms. This is the only sampling method that boasts a 99.9% retention rate for airborne microorganisms compared with 40%-60% for other collection methods. It is also the only method capable of reliably collecting airborne viruses. Due to the porous nature of the filter, all bacteria-laden particles are captured, regardless of size and the residual moisture content of the filter prevents desiccation of the retained organisms. Filters are pre-sterilized (gamma irradiation), single or triple bagged, H2O2 safe and disposable.

direct_method After sampling, there are two filter transfer methods: direct and indirect. Using the direct method, the filter is placed directly on an agar nutrient plate. The gelatin filter dissolves, leaving the microorganisms in direct contact with the plate. Using the indirect method, after sampling, the gelatin filter is dissolved in a sterile solution. The solution is then membrane-filtered and the filter disk is placed on an agar medium. The indirect method is useful for special evaluations, such as when inhibitors are present in the air being sampled, high colony counts are expected or when microorganisms collected are to be incubated on several different agar types simultaneously. When the virus concentration is to be determined, the indirect method must be used so that retained viruses can be cultivated in the solution and analyzed by virological or molecular biological methods.
airport_images3

 

Specs

AirPort MD8
Air flow control by an integrated impellar wheel
Pre-set air flow rates 30 l/min, 40 l/min, 50 l/min
Pre-set sample volumes (liters) 25, 50, 100, 250, 500, 750, 1000
Table of correlation of sampling volumes/ sampling times at the given flow rates
Sampling volume in liters
25 50 100 250 500 750 1000
Sampling time in seconds
at 30 l/min flow rate 50s 100s 200s 500s 1000s 1500s 2000s
at 40 l/min flow rate 37.5s 75s 150s 375s 750s 1125s 1500s
at 50 l/min flow rate 30s 60s 120s 300s 600s 900s 1200s
Additional user-definable sampling volumes from 10 to 2000 liters in 5-liter increments
Total sampling time with one battery approx. 4.5 hours at 50 l/min
Power consumption 5-14 Watt dependent of filter pressure drop
Noise level 48 dB (A) max
Weight approx. 2.5 kg
Dimensions (L x W x H) in mm 300 x 135 x 165

Gelatin Filter Disposables

AirPort MD8
Air flow control by an integrated impellar wheel
Pre-set air flow rates 30 l/min, 40 l/min, 50 l/min
Pre-set sample volumes (liters) 25, 50, 100, 250, 500, 750, 1000
Table of correlation of sampling volumes/ sampling times at the given flow rates
Sampling volume in liters
25 50 100 250 500 750 1000
Sampling time in seconds
at 30 l/min flow rate 50s 100s 200s 500s 1000s 1500s 2000s
at 40 l/min flow rate 37.5s 75s 150s 375s 750s 1125s 1500s
at 50 l/min flow rate 30s 60s 120s 300s 600s 900s 1200s
Additional user-definable sampling volumes from 10 to 2000 liters in 5-liter increments
Total sampling time with one battery approx. 4.5 hours at 50 l/min
Power consumption 5-14 Watt dependent of filter pressure drop
Noise level 48 dB (A) max
Weight approx. 2.5 kg
Dimensions (L x W x H) in mm 300 x 135 x 165

Calibration Unit

Calibration Unit
Measuring range min. 1.6 m3/h max 16 m3/h
Max error of measuring system up to 3.2 m3/h = +/- 3%; 3.2-16 m3/h = +/- 1.5%
Current consumed by the electronic circuitry for measurement 8 mA3
Pulse output 5,000 pulses= 1m3
Allowable ambient temperature -10oC…+40oC
Allowable temperature of the media -10oC…+40oC
Allowable humidity (rel.%) 30-80%
Type of protection IP 40 during operation with filter holder, connector hose and PVC
Hours of operation with fully charged battery pack approx. 70hrs
Time needed to completely recharge battery 30hrs
Weight approx. 5.6 kg
Dimensions (L x W x H) in mm 295 x 174 x 246

Related Products

airscanmd8

Sartorius AirScan MD8

Designed specifically for use in isolators and clean room environments. Comes standard with a flexible, PVC hose and is capable of high flow rates; 1 m3 in less than 8 minutes. Utilizes the gelatin membrane filter sampling method which is the only method...

Full Product Details...

samplair

Sampl'Air

Portable air samplers utilizing the impaction sampling method. Air is drawn in and directed toward a Petri dish with a suitable collection media. Microorganisms are then impacted on the media. Available in two different models, the Sampl’Air Lite and S...

Full Product Details...

 

 

 

 

 

 

 

 

 

 

 

 

My Account






Lost Password?
Forgot your username?
No account yet? Register

Show Cart
Your Cart is currently empty.

milogo

Online Consumables Search

Site Search

contactus

Microbiology International
5111 Pegasus Ct.
Suite H
Frederick MD 21704

p:800EZMICRO (396-4276)
p:(301)662-6835
f:(301)662-8096

©2010 Microbiology International
Automating the world, one lab at a time

Privacy Policy 

About Us