Whitley Workstation MG-500
![]() |
The Whitley Workstation MG-500 has a 540 plate capacity and is constructed of rigid acrylic (6mm thick front panels, 10mm thick side panels). The panels are chloroform annealed, creating a uni-body construction capable of withstanding positive pressure well in excess of the 4 PSI maintained constantly by the system. |
|
Whitley Workstation MG-500 shown with optional airlock
|
![]() |
|
Patented use of Anotox (activated carbon impregnated with ferric hydroxide) for atmospheric conditioning. By using Anotox, the catalyst does not have to be removed and baked routinely. Anotox removes the Hydrogen Sulfide and volatile fatty acids (by-products of anaerobe metabolism) that poison the catalyst and can impede the growth of anaerobes. The entire workstation is temperature controlled, allowing for temperatures between 4C and 44C. There is no need for extra incubators and loss of space efficiency. |
|
| Humidity is controlled automatically by an electronically controlled water removal system. Water is pumped to a container containing a silver-impregnated bacteriostatic wick to evaporate the water externally. There are no containers to empty. The humidity setting is user programmable. | ![]() |
|
The electronics and lighting are located in an external control housing. There is no need to compromise the workstation to change light bulbs or perform fuse replacement. The 100 plate airlock is an option to the Whitley Workstation MG-500. The airlock cycle is electronically controlled and requires only a press of a button to operate. Catalyst dedicated to the airlock is housed internally and does not need to be changed or replaced. |
|
| The system uses a radio controlled footswitch to eliminate clumsy wiring. There is a manual override for use when necessary. | ![]() |
![]() |
![]() |
| There are audible alarms to notify the user of low gas pressure, gas leaks, or power failure. The system is capable of maintaining anaerobiosis in the event of power loss for up to 24 hours. | |
Specs
| Whitley Workstation MG-500 | Whitley Workstation MG-500 w/airlock | |
| Dimensions (L x D x H) in mm |
1040 x 760 x 800 | 1570 x 760 x 840 |
| Weight (Kg) | 100 | 155 |
| Gas Requirements | 1 x ANO2 (10% H2, 10% CO2, 80% N2) or 1 x ANO2 and Nitrogen |
1 x ANO2 (10% H2, 10% CO2, 80% N2) or 1 x ANO2 and Nitrogen |
| Gas Consumption (on average) |
4-6 weeks on 2000 lb tank | 4-6 weeks on 2000 lb tank |
| Power Requirements | 110 V, 50-60 Hz | 110 V, 50-60 Hz |
| Working Capacity | 540 x 90 mm plates | 540 x 90 mm plates, airlock can transfer 90 x 90 mm plates |
Options
|
Whitley Workstation Airlock Module Three gases (TG) or mixed gas (MG) options available. For the fasted automated transfer time possible without compromising workstation conditions. Comes with sliding tray for easy transfer and has a 90 x 90mm plate capacity + space for sundries. The airlock cycle takes about 5 minutes to complete, once finished, the airlock is accessed from inside the chamber via a one-button elevator door. (Available as an upgrade option to add to existing workstations) |
![]() |
|
Refrigeration Unit Designed to maintain a lower than normal temperature within the incubation and working area. The standard refrigeration unit is designed to operate at 8±10C when located in an ambient temperature of 21±20C. Other set temperatures are achievable, but require discussion with our product development department in advance. |
![]() |
| Single Plate Entry System For rapid transfer of individual plates into the chamber |
![]() |
Accessories
|
-Microscope and Bracket A long focal length microscope, complete with bracket, fixtures and fittings. |
![]() |
|
-HEPA filtration unit The HEPA filtration unit is available for all Whitley Workstation systems and recommended for BSL2 and higher safety environments. Atmosphere within the chamber is exhausted during normal cycle operations. This exhaust air can be filtered through the optional HEPA filtration system to avoid contamination of the lab environment. The system is comprised of dual stage filter units that are easily replaced every six months. |
![]() |
|
-Orbis Microplate and Tube Shakers The Orbis shaker is a compact choice of microplate shaker for any test environment. It is small enough to fit easily into your Whitley Workstation chamber for use with organisms requiring the strict atmosphere. With a footprint marginally larger than that of the microplate it shakes, the Orbis offers the most advance solution for your shaking applications. The counter-balanced orbital movement guarantees a stable, quiet and life long operation. The Orbis shaker can be operated as a microtube shaker when used with an accessory tube platform. |
![]() |
|
- Basket tag set. 20 x 7 colors, perfect for organizing your chamber. |
![]() |
|
-10 plate Petri dish holder. -20 plate Petri dish holder. Used in conjunction with the 20 Plate Adaptor Kits -30 plate Petri dish holder. For users with an Airlock Module. |
|
|
-Whitley Workstation 20 plate Adaptor kit. Converts each porthole to be capable of transferring up to 20 plates in or out of the workstation at any one time. |
![]() |
|
-Whitley Workstation Trolley. A purpose-designed tubular steel trolley of welded construction with white powder-coated finish, equipped with heavy duty castors for ease of mobility. Available for 500 and 1000 workstations. (Whitley Workstation MG-1000 trolley, with airlock extension shown)
-Whitley Workstation Airlock Trolley. Converts any MACS 500 or 1000 trolley to accommodate an airlock. |
![]() |
Related Products
Video
|
|