Anaerobic Hypoxic Systems
Hypoxystation
Hypoxystation
![]() |
The HypOxystation incubator chamber is used in the study and isolation of microaerophilic and microaerobic organisms such as Campylobacter spp and Helicobacter pylori and other similar organisms. Up to three gases - nitrogen, carbon dioxide, and air, can be combined within safe and varying ratios to provide a specific atmosphere. A microprocessor controls and maintains the selected mixture.
The touchscreen interface allows you to monitor all settings and eliminates the need for other dials, switches and gauges. The transfer airlock provides effective sample transfer to and from the chamber. An optional removable front design allows set up of larger equipment needed inside the chamber. The ergonomic gloveports for gloved or bare hand working make HypOxystation comfortable for in situ manipulations.
Features
Control O2 in 0.1% increments from 0.1% - 20%
Control CO2 in 0.1% increments from 0.1% - 15%
Straightforward calibration of gas sensors without removing sensors from chamber or disrupting the working atmosphere
Control temperature easily and precisely
Control relative humidity up to 85%
Touch screen interface to monitor all parameters simultaneously
Real time feedback system monitors and adjusts O2 levels to insure accuracy. CO2 is also available
Integrated gas control minimizes bench space requirements – no bulky external gas mixing system
Data logging of all parameters for up to 30 days
USB port for data transfer
Specs
| HypOxystation H35 | |
|
External Chamber Dimensions (L x H x D) in mm |
1233 x 710 x 722 |
| Internal Chamber Dimensions (L x H x D) in mm | 865 x 430 x 400 |
| Airlock Dimensions (L x H x D) in mm | 223 x 254 x 190 |
| Airlock Door Opening (W x H) in mm | 200 x 190 |
| Power Requirements | 115V; 20 Amp; 50-60 Hz |
| Weight (Kg) | 155 |
Options
The HypOxystationTM has been designed specifically for microbiologists requiring the ability to accurately control oxygen, temperature and humidity. Options are available for researchers to customize the system based on need:
Humidity Control System - 500ml external reservoir, control relative humidity up to 85% via touch screen.
Removable Front – With panel removed an opening exists large enough to allow an object measuring u to 30.5” x 15.5” to be introduced into the incubator chamber. The design of the opening also means that a slimmer, wider object measuring up to 32.75” x 8” could be introduced as an alternative.
CO2 Monitoring – Hardware and software provided to monitor and control CO2 in 0.1% increments from 0.1% to 15%
15cm Letterbox – A 15cm wide opening with unique door mechanism allows the user to introduce larger plates and other items into the workstation quickly and efficiently without having to run an airlock cycle. Positive pressure inside the chamber ensures that outside atmosphere does not affect internal gas mixture.
Double Internal Power Socket –Two standard outlets are provided which can provide up to 1 amp of 115V power for charging pipettors, cell rollers, etc.
Vacuum Take-off Port – Quick connect fittings are attached to and small port on the left side of the instrument, allowing a vacuum pump operating outside of the instrument to draw against any size tubing and extraction mechanism inside the workstation.
Automatic Sleeve Gassing System – Hardware and software provided to allow the user to press and hold the foot switch for automatic removal of atmospheric gases from the sleeves. Vacuum and gas pressure are monitored assuring consistent procedure of entry by technicians.
Internal Storage Tray – Maximum of two per unit. 22x26x2.5cm. Trays are mounted under shelf for easy access and minimum intrusion of space.
Spare Cable Gland – A small port with temporary completely sealed enclosure that can be used to place wires or tubes into workstation.
Gas Sample Port – A small port with quick connection and one way gas flow for sampling of internal atmosphere for independent verification of O2 and CO2 levels or presence of contamination.
Data logging - Keeps track of up to 30 days of your various gas levels and the data can be transferred to a USB flash drive.
Regulator:
|
Forged Brass Body |
Forged Brass Body Stainless Steel Diaphragms Diaphragm Valve 0-125psig Delivery Pressure Range 0-200psig Delivery Pressure Gauge 0-4000psig Cylinder Pressure Gauge 6MM Quick Connect Outlet CGA 320 for Carbon Dioxide |
Forged Brass Body |
|
|
||