Autoclaves
HX Series
HX Series
Features
HX Series Autoclaves
|
Take a look at our larger line of large autoclave units that offer massive loading capacities. HX Series Autoclave units come in 210, 320, 430 and 540 liter capacities. Pass through (double door) models are available in sizes of 320, 430 and 540 liter capacities.
|
|
|
Easy and safe. When the lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds the seal becomes tighter. The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle. The door-locking system is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and touchscreen interface, is made of heat resistant and insulated plastic. There is no risk of the operator coming into contact with hot components. |
![]() |
|
|
Pressure-safe up to 5 bar/150 °C. Systec HX-Series large autoclave units are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure |
|
Controls – new generation. Menu-presented instructions in easy to read text form. Touchscreen pad with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position. |
![]() |
|
|
Steam generation! – No heating elements and no reservoir for dirty water in the chamber Condensation instead of steam removal! |
| Further standard features: – Flexible temperature sensor PT-100 for a reference vessel – Medium temperature triggering of sterilization time – Autofill – automatic filling with demineralized water feed for steam generation – Start by clock – timer for programming starting time – Collecting point for all outlet pipes – Venting valve – Baseplate in the chamber for vessels, baskets etc. – Validation port |
![]() |
Specs
| Horizontal Autoclaves - 1 Door | Pass Through Autoclaves - 2 Doors | ||||||||
| Type | HX-210 | HX-320 | HX-430 | HX-540 | HX-650 | HX-320-2D | HX-430-2D | HX-540-2D | HX-650-2D |
| Chamber Dimensions in mm (diameter x depth) |
740 x 500 | 740 x 750 | 740 x 1000 | 740 x 1250 | 740 x 1500 | 740 x 750 | 740 x 1000 | 740 x 1250 | 740 x 1500 |
| Chamber Volume in Liters | 210 | 320 | 430 | 540 | 650 | 320 | 430 | 540 | 650 |
| External Dimensions in mm (W x D x H) |
930 x 1035 x 1780 | 930 x 1285 x 1780 | 930 x 1535 x 1780 | 930 x 1785 x 1780 | 930 x 2035 x 1780 | 930 x 1210 x 1780 | 930 x 1460 x 1780 | 930 x 1710 x 1780 | 930 x 1825 x 1780 |
| Weight (in kilograms) | 370kg | 405kg | 445kg | 485kg | 525kg | 565kg | 605kg | ||
| Electrical Connections | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* | 220V 3 phase 60 Amps* |
|
*Modification of electrical requirements are possible on a case by case basis |
|||||||||
Options
|
Autoclave Cooling Options For liquid cycles all large Systec autoclave units directly measure the temperature of the liquid being sterilized, NOT chamber temperature like most autoclave units. Once liquids have been heated to 121oC and sterilized they must be cooled to a safe temperature before allowing operator access to the chamber. The longest part of the sterilization cycle for liquids is the cool down phase (see graph below). Large Systec autoclave units offer three cooling options that can significantly reduce the cooling time for liquids after sterilization is complete. Faster cool down times allow for increased throughput and faster availability of liquids after sterilization.
|
Level 1 - Cooling coils with support air pressure.
| Level 1 cooling provides a coil wrapped around the outside of the sterilization vessel. During the cooling phase cool water circulates through the coils reducing cool down time (see graph). Support pressure eliminates evaporative loss of the sterilized liquids during cooling. | |
![]() |
![]() |
Level 2 - Cooling coils with support air pressure and radial ventilator.
| Level 2 cooling provides the benefits of Level 1 cooling with the addition of a radial ventilator for air circulation and accelerated heat removal from the liquids (see graph). Support pressure eliminates evaporative loss from the liquids during cooling. | |
![]() |
![]() |
|
|
|
Level 3 - Cooling coils with support air pressure, radial ventilator and UltraCool.
|
Level 3 is our fastest cool down option. In addition to cooling coils and radial ventilator UltraCool incoporates a special cooling coil below the radial ventilator reducing cool down times by 50% (see graph) compared to level 2 cooling. As with the other cooling options support pressure eliminates evaporative loss from liquids during cooling. |
|
![]() |
The UltraCool option is shown attached without the radial ventilator cover. |
![]() |
The UltraCool option is shown attached with the radial ventilator cover. |
Additional Large Autoclave Options
|
Printer for documentation Print program type, batch number, date, time, temperature, pressure and sterilization phase for total traceability |
|
| Vacuum System - Required for Superdry option, but also allows for fractionated pre-vacuum. Useful for sterilization of waste bags, porous materials, hollow items and textiles. | |
| "Superdry" provides efficient drying of solids, hollow items (ie. pipette tips) and porous items (ie. filters and textiles). |
Installed steam generator supplies heat to coils that surround sterilization vessel. Rapid surface drying occurs due to the heat and the chamber being under a vacuum. |
| Air Exhaust Filtration - the exhaust air is filtered via an autoclavable sterile filter. Neither aerosoles nor microorganisms can escape before the sterilization process is complete |
Filter cartridge with PTFE membrane, pore size 0.2 um. |
| Magnetic Stirrer - for stirring of liquids in large vessels during the sterilization process. |
|
| Extension of temperature and pressure range up to 150 C and 5 bar | For material testing and other special applications where increased temperature are required. |
| Transport and Loading Carriages available for all models |
|
Accessories
|
|
|
|
PC software For documentation during sterilization program. Download and save all cycle information. Additional use for service and diagnosis of instrument electronics. |
![]() |
|
Stainless Steel closed basket for waste sterilization Used for waste sterilization |
![]() |
|
Stainless Steel Wire Mesh Basket Used for sterilizing liquids, open containers, non-waste materials |
| Air compressor – Silent 200 Used for quick cooling if compressed air is not available |
| Conductivity meter For validation of PT100 temperature probes |
| Condensate collection vessel For units not connected to constant De-Ionized water supply |
| Demineralization cartridge Stainless steel. For connection to “hard” water supply |